Model
Capacity
Dimensions
Static Water (Gallons)
º Grease
Capacity
(lbs.)
Inlet/Outlet (Diameter)
Inlet/
Outlet
(Height)
Length
Width
Height
AGI-15
1'10.25"
1'0"
1'2"
9.2
56
2"/2"
9"/9"
AGI-20
2'2.25"
1'2"
1'6"
12.7
70
2"/2"
9"/9"
AGI-25
2'9"
1'4"
1'6"
17.1
92
3"/3"
9"/9"
*AGI-L25
3'4"
1'4"
1'6"
14.8
95
3"/3"
6"/6"
*AGI-H25
3'0"
1'5"
1'7"
22.5
120
3"/3"
10"/10"
AGI-35
3'0"
1'6"
2'2"
43.5
234
3"/3"
17"/17"
AGI-50
3'4"
1'6"
2'8.25"
50
283
4"/4"
18"/18"
AGI-75
4'0"
1'6"
2'11.75"
75
424
4"/4"
22"/22"
AGI-100
5'0"
1'8"
2'11.75"
103.9
599
4"/4"
22"/22"
AGI-150
6'0"
2'6"
6'3.5"
232
1,220
4"/4"
**/48"
AGI-200
7'6"
2'6"
6'3.5"
290
1,507
4"/4"
**/48"
AGI-250
9'0"
2'6"
6'3.5"
341.5
1,782
5"/5"
**/48"
AGI-400
13'0"
2'6"
6'3.5"
493
2,585
5"/5"
**/48"
AGI-600
14'6"
2'6"
6'3.5"
697
3,840
6"/6"
**/48"
AGI-800
18'0"
2'6"
6'3.5"
837
4,550
6"/8"
**/48"

* L - Low-profile design, H - High-profile design.

** Inlet can be directed through top or back of unit. Minimal height adjustment can be specified - Contact Areo for assistance.

º National Plumbing Code requires a minimum 2 lbs. of grease retention for each GPM of flow. Grease holding capacity at breakdown is determined by a minimum 85% efficiency rating in real life applications and installed according to specification.

Note: From Models 150 through 800 add 6 gals. per foot for V-bottom