Areo PetroBox Fueling System |
|
![]() |
Completely Assembled - Ready to Go Fueling System |
| Capacities and Drawings | |
| Request Tank Pricing | |
| PetroBOX systems can be equiped for Aviation Gasoline (100LL), Gasoline, and Diesel applications. | |
|
PetroBOX® Tank Fueling System The PetroBOX Tank Fueling System is designed around a two time-tested and industry proven storage tanks - the Fireguard® and Flameshield®. PetroBOXTM Fueling Systems are available in either cylindrical or rectangular configurations and feature double-wall construction. Each tank is fabricated with integral filing and dispensing systems. Because they are above ground tanks, they can be easily relocated if necessary. Dispensing System Features Standard Features Tank Construction Fireguard® "Fire-Protected" tanks have a minimum 3" of lightweight insulating material between the tank walls. They are used where a fire-protected tank is needed because of setback limitations and/or regulatory insistence for storage of flammable and combustible liquids. These tanks are Underwriters' Laboratories UL-2085 labeled for Fire Protection, Impact Resistance, Ballistics Resistance and Secondary Containment. Flameshield® tanks are manufactured to strict STI specifications and are subject to the Steel Tank Institute's Quality Assurance program. Each Flameshield® constructed tank carries the Flameshield® and SwRi 97-04 labels. |
|
| Capacities and Drawings | |
|
|
|
| |
|
|
Guideline Specification Provide and install a ______ gallon PetroBOX® (Fireguard® or Flameshield®) Double-wall Steel, Aboveground Storage Tank System. Tank storage volume shall be ______ gallons. Approximate weight shall be ________(lb.). The PetroBOX® shall be designed for aboveground storage of flammable and combustible liquids at atmospheric pressure. PetroBOX® shall include integral steel secondary containment. The Fireguard® model includes thermal insulation that provides a minimum two-hour fire rating. Each tank shall be delivered as a complete UL-listed assembly with factory supplied supports. Tank to be set level on a solid foundation. PetroBOX® shall be designed for possible relocation at a future date. Concrete encased tank designs are not equal and will NOT be permitted. Tank shall comply with the latest edition of National Fire Protection Association NFPA 30 Flammable and Combustible Liquids Code. The tank’s secondary containment must be tested for tightness in the factory and in the field before commissioning. Tank shall be supplied with emergency vents for the primary and the secondary containment tanks. Emergency venting by “form of construction” is not equal and will NOT be permitted. Inner and Outer Tank shall be manufactured in accordance with UL-142 Standard for Steel Aboveground Tanks for Flammable and Combustible Liquids. Flameshield® models shall be labeled for Underwriters Laboratories UL 142 and swRI –9704. Fireguard® models shall be labeled for Underwriters Laboratories UL 2085 Standard for Insulated Secondary Containment Aboveground Tank for Flammable and Combustable Liquids. Fireguard® models shall comply with UL 2085 “Protected” Tank standards that include: Ballistics, Impact, Hose Stream, and Pool Fire. The Fireguard® model shall be manufactured and labeled in strict accordance with Steel Tank Institute (STI) Fireguard® Thermally Insulated, Double-wall Steel Aboveground Storage Tank standards as applied by a licensee of the STI. Both the Fireguard® and the Flameshield® Tank shall be subject to the STI’s Quality Assurance program and shall be backed by the STI 30 year limited warranty. Construction Tank shall be of double wall construction and provide complete secondary containment of the primary storage tank’s contents by an impervious steel outer wall. The Fireguard® model includes a minimum of 3” of porous, lightweight monolithic thermal insulation material shall be installed at the factory within the interstitial space between the inner and outer wall. Thermal insulating material: Lifting lugs shall be provided at balancing points to facilitate handling
and installation.Exterior Protective Coating: Threaded fittings with thread protectors shall be supplied as follows (all fittings must be located on tank top per UL): Accessories System Power Requirement Optional Equipment Execution |
|
|
Areo Power Unitized Fueler Inc., 103 Smithtown Blvd,
Smithtown, NY 11787
|
|
|
(800)242-2736 · (631)366-4362 · Fax (631) 366-0905 ·
info@areotank.com · www.areotank.com
|
|